How to Access Diagnostic Modes on a Maytag Washing Machine
MaytagMaytag Washing MachineModerate⏱ 10 - 20 minutes
Инструкция на английском (оригинал iFixit). Непонятные термины — в разделе «Основы → Словарь».
Use this guide to open your Maytag vertical modular washer, retrieve the hidden technician sheet, and work through each built-in diagnostic feature. Reading stored error codes, running tests, and performing the required recalibration will reveal many spin, drain, or fill problems before you replace parts unnecessarily.
🧰 Tools
- 1/4" Nut Driver
- TR10 Torx Security Screwdriver
- Painter's Tape
- Wood Block
ШагиSteps
1
Remove the three rear screws
- Use a 1/4" nut driver to remove the two top screws and the single harness-plate screw on the rear panel.
2
Pivot the top panel upward
- Pull the lid toward you, lift slightly, then slide it back so the hinges support the top as it tilts open.
3
Retrieve the technician service sheet
- Reach under the front left corner of the raised top and pull out the folded technician sheet for code references.
4
Reset the cycle selector knob
- Rotate the knob counter-clockwise until it is at the 12 o’clock position, completing one full turn to ensure a clean starting point.
5
Enter diagnostic mode
- Turn the knob right three clicks, left one click, then right one click, pausing about half a second between moves.
6
Scroll through diagnostic sub-menus
- Turn the knob clockwise to cycle in order through Error Code, Automatic Test, Manual Test, and Recalibration selections.
7
Retrieve and clear stored error codes
- Stop at the Error Code position where only the Cycle Complete LED is lit and press Start to enter code recall.
- Rotate the knob clockwise to display up to four saved fault codes one by one.
- After the fourth code, turn once more to make all LEDs flash; hold Start for about five seconds here to erase every stored code if needed.
8
Run the automatic component test
- Select Automatic Test and press Start; the washer will cycle all major components in roughly three minutes.
9
Use manual test mode for targeted checks
- Select Manual Test and press Start to enter, then rotate the knob to the function you want to examine.
- Press Start to run the chosen action and press it again to stop that action at any time.
- Choose the lid-lock option first if you intend to run spin or agitation tests because those functions will not work with the lid unlocked.
- Hold Start for three to four seconds to cancel manual mode and return the control to the off position.
10
Perform washer recalibration
- From the main diagnostic menu, turn the knob four clicks clockwise until only the Rinse LED is illuminated.
- Press Start to begin recalibration; the washer resets each control parameter and performs a brief verification sequence lasting about two and a half minutes.
11
Reinstall the top panel and screws
- Lower the lid back onto the hinges, slide it forward into place, and press down firmly.
- Reinsert the harness-plate screw and the two top screws to secure the panel with the nut driver.
Exit diagnostics after recalibration and use the stored codes and test results to guide any needed repairs. Repair didn't go as planned? Ask our Answers community for help.